Abstract:
Osteoarthritis (OA) is a chronic musculoskeletal disease affecting over 500 million people globally, characterised by cartilage degeneration and new bone formation at the articular surface, with the knee being the most commonly affected joint. Whilst more conservative therapies exist such as lifestyle changes or NSAIDs, most OA patients don’t seek help until they are in pain, by which point the condition has already significantly progressed. Combined with an ageing population, this has meant more and more individuals are requiring total knee replacements (TKRs), the only potentially curative approach for end-stage disease. However, 15-20% individuals are still in pain post-op – extensive research is ongoing into the development of curative molecular therapies for OA, but nothing of clinical promise has materialised thus far. An alternative option is to utilise medical technology to improve the success ratio and patient satisfaction in TKRs. Two such improvements that could be the future of orthopaedics are robot-assisted surgery and 3D-printed knee implants. This article will explore these technologies in terms of how they work, their potential to improve on current protocols, their limitations preventing rapid implementation into public healthcare settings, and their application to a range of musculoskeletal conditions.
Can Robots Build a Better Knee?
The RACER-Knee trial (2021-2033), led by Andy Metcalfe and Edward Davis, is an ongoing double-blind randomised control trial on patients with primary knee OA, run jointly by University Hospitals Coventry and Warwickshire, University of Warwick and Royal Orthopaedic Hospital in Birmingham. It received £1.6 million in funding by the NIHR, and aims to answer the question if intraoperative robotic-arm technology can provide better surgical outcomes in TKRs and enhance the care surgeons provide in comparison to standard instruments, to see which joint replacement method is best value for the NHS moving forward. Patients due to undergo TKR are randomly allocated to the standard instruments (control) or robot-assisted group, the latter constituting a surgeon-controlled robotic arm directing surgical instruments into the correct positions to cut the bone according to a pre-programmed 3D plan via sensing leg position; knee implants are then inserted with cement as is done traditionally. The Stryker MAKO robotic system is the most commonly used robotic arthroplasty system worldwide – pins are inserted into the top of the skin via two small 1cm incisions, to show the computer where the bones are during surgery. Both groups will receive these incisions to ensure participants don’t know which group they are in – they will not be used in control group participants. The primary outcome of the trial is the forgotten joint score (FJS), a questionnaire in which patients are asked to self-report the level of awareness of their artificial joint during 12 different everyday activities. A score from 0-100 is calculated, with a higher score corresponding to a better outcome in terms of quality of life and patient satisfaction. Whilst this is good at encompassing a range of tasks in which pain could arise, it still possesses prominent limitations. For example, if 3 or more of the 12 questions are left unanswered, which is a highly possible outcome early post-op, no score is calculated. Early pain, hours from end of surgery to discharge, and alignment of the components are all secondary outcomes measures, with researchers additionally conducting follow-up questionnaires 2, 5 and 10 years post-op.
The Debate
This is an ongoing trial so results are yet to be released, but clinicians currently have split opinions on robot-assisted surgery. Its use in orthopaedics has increased rapidly in recent years, however there is little evidence thus far to prove its superior efficacy over conventional surgery. The main argument in favour of its use is that the improved surgical precision it provides will reduce post-op pain and improve function, whilst also reducing the likelihood of expensive revision surgery. However it does add additional costs to a surgery which may be just as successful and quicker if performed with conventional instruments, with an argument being that human decision making surrounding the precision of bone cutting can sufficiently match that of a robot without the added expense. Conventional surgery also does not require the drilling of holes for pin placement, which has a very small chance (<1/1000) of causing bone fracture. Hopefully the conclusion of this study will be able to answer the much-debated question of whether robotic guidance does indeed result in less pain in the first few days post-op and an improved quality of life long-term.
Can 3D printing personalise knee replacements?
Typical knee implants are made from materials such as titanium and cobalt-chromium alloys, but the current standard of care involves the use of off-the-shelf components that come in various pre-designed sizes. However anatomy is not universal, each individual possesses unique joint structure – so it makes sense that when a joint is in need of replacement, rather than forcing their body to match the implant, custom implants tailored to the patient would ensure the best chance of success. The introduction of 3D printing technology to orthopaedic surgeries such as knee arthroplasties has the potential to transform the practice entirely, facilitating the creation of bespoke implants and surgical instruments tailor-made for the unique anatomical and pathological challenges OA patients often present with.
One Goal, Two Different Solutions
AdlerOrtho and Conformis are two companies retailing knee implants on different scales of customisation. In 2007, AdlerOrtho became the first company worldwide to produce a 3D-printed implant in series, and began to produce custom-made implants from 2010. However, it primarily uses printing technology in conjunction with an additive manufacturing technique whereby metal powder is added layer by layer to form solid structures with a 3D porous lattice surface otherwise impossible to make, producing advanced anatomical implants. Conformis on the other hand is a market leader in truly patient-specific implant manufacturing at a commercial level. Their general method of production involves turning high resolution CT or MRI scans into accurate 3D digital models of a patient’s knee joint, taking into account any underlying deformities, such as bone spurs or flattening of the joint. Engineers and surgeons then coordinate to produce prostheses and surgical cutting guides unique to the patient.
The Trade-Off
These two different approaches essentially bring to light the trade-off of standardisation vs customisation. Although AdlerOrtho’s implants are not fully custom they possess alternative advantages, such as easier revision planning and intraoperative flexibility, meaning implant size is more easily changed mid-operation if real-time anatomy differs from the pre-operative imaging, like if there is more bone loss than anticipated. The tailor-made fit of Conformis implants to exact patient measurements results in better kinematics and mechanical alignment to improve TKR outcomes. It maintains the patient’s natural joint lines to promote a more natural and stable knee movement, for increased patient satisfaction and less discomfort post-op. However there are drawbacks preventing their mass implementation clinically – the lack of long-term data available at this point in time makes the NHS reluctant to pay the additional cost until its superior efficacy is reliably proven. Their production also requires a complex regulatory process that must be coordinated between engineers and surgeons so that the CT imaging, engineering design, manufacturing and delivery are carried out in the correct timeline consistently.
What Does the Future Hold?
Robotics and 3D-printing are two arms of technology that are capable of revolutionising joint replacement surgery to improve intraoperative precision and post-operative outcomes in TKRs. However at present, the lack of clinical data available to back-up their supposed greater efficacy hinders widespread adoption. Whilst conventional instruments and implants will likely continue as the standard of care for a while yet as a result, these techniques hold a lot of promise for the future of orthopaedics. OA is the primary beneficiary for this technology thus far, but their use has the potential to extend to other conditions in which mass bone loss can occur such as rheumatoid arthritis, congenital knee deformities, and osteosarcoma.
References:
- AdlerOrtho, 2026. AdlerOrtho. [Online]
Available at: https://www.adlerortho.com/
[Accessed 16 7 2026]. - Conformis, 2026. Conformis. [Online]
Available at: https://www.conformis.com/en-uk/
[Accessed 16 7 2026]. - Haertle, M., Tuecking, L.-R., Derksen, A. & Hold, M., 2025. CURRENT INNOVATIONS IN 3D-PRINTED IMPLANTS AND INSTRUMENTS FOR KNEE AND HIP ARTHROPLASTY. ResearchGate, 107-B(7), p. 49.
- ISRCTN, 2024. ISRCTN. [Online]
Available at: https://www.isrctn.com/ISRCTN27624068
[Accessed 16 7 2026]. - Khatri, C. et al., 2024. Robotic trials in arthroplasty surgery. The Bone & Joint Journal, 106-B(2), pp. 114-120


Leave a Reply